CRP Rapid Test


Biopanda Reagents offers three types of Rapid Tests for C-reactive Protein (CRP) as follows:

Qualitative CRP Rapid Test

Product Number: RAPG-CRP-002

Pack size

10 tests

Product Description

The Biopanda CRP Rapid Test is a lateral flow chromatographic immunoassay for the qualitative detection of human C-reactive protein (CRP) in whole blood, serum, and plasma samples. This test is a tool to assist in the diagnosis of inflammatory conditions. The cut-off value for this test is 10 mg/L.

Test Attributes

  • Whole blood, serum, or plasma may be used for testing
  • Results available in only 5 minutes
  • Easy to use
  • Results can be read visually
  • No need for an analyser
  • Cost effective method to assist in the diagnosis of inflammatory conditions

Test Procedure

  1. Ensure specimen and test kits are brought to room temperature before testing.
  2. Open the foil wrapped pouch and remove the cassette, placing it on a flat, clean surface. Use the test as soon as possible or within one hour of opening.
  3. Hold the dropper vertically and transfer 3 drops of the diluted specimen (approx 120 μl) to the specimen well of the cassettes and start the timer.
  4. Wait for the coloured line(s) to appear. Read results at 5 minutes.  Results read after 10 minutes are considered invalid.


Principle

The Biopanda  CRP Rapid Test is a qualitative, membrane based immunoassay for the detection of CRP in whole blood, serum or plasma. The membrane is pre-coated with specific capture antibodies in the test line regions of the test. During testing, the whole blood, serum or plasma specimen reacts with the particle coated with specific antibodies. The mixture migrates laterally along the membrane chromatographically by capillary action to react with specific capture reagents on the membrane and generate a coloured line. The presence of this coloured line in the specific test line region indicates a positive result, while its absence indicates a negative result. To  serve  as  a  procedural  control,  a  coloured  line  will  always  appear  in  the  control  line  region indicating that proper volume of specimen has been added and membrane wicking has occurred.

Performance Characteristics

  • Relative sensitivity: 96.7%
  • Relative specificity: 98.5%
  • Accuracy: 98.3%

Storage Conditions

Store the kit between 2-30°C and ensure the kits are not frozen or stored in direct sunlight. The test is valid until the expiration date printed on the foil wrapping.

Semi-Quantitative CRP Rapid Test

Product Number: RAPG-CRP-102

Pack size

10 tests

Product Description

The Biopanda CRP Semi-Quantitative Rapid Test is a lateral flow chromatographic immunoassay for the Semi-Quantitative detection of human C-reactive protein (CRP) in whole blood, serum, and plasma samples. This test is a tool to assist in the diagnosis of inflammatory conditions. The cut-off value for this test is 10 mg/L.

Test Attributes

  • Whole blood, serum, or plasma may be used for testing
  • Results available in only 5 minutes
  • Easy to use
  • Results can be read visually
  • No need for an analyser
  • Cost effective method to assist in the diagnosis of inflammatory conditions

Test Procedure

  1. Ensure specimen and test kits are brought to room temperature before testing.
  2. Open the foil wrapped pouch and remove the cassette, placing it on a flat, clean surface. Use the test as soon as possible or within one hour of opening.
  3. Hold the dropper vertically and transfer 3 drops of the diluted specimen (approx 120 μl) to the specimen well of the cassettes and start the timer.
  4. Wait for the coloured line(s) to appear. Read results at 5 minutes.  Results read after 10 minutes are considered invalid.


Principle

The Biopanda CRP Semi-Quantitative Rapid Test detects C-reactive Protein through visual interpretation of colour development on the internal strip. Anti-CRP antibodies are immobilized on the test region of the membrane. During testing, the specimen reacts with anti-CRP antibodies conjugated to coloured particles and pre-coated on the sample pad of the test. The mixture then migrates through the membrane by capillary action, and interacts with reagents on the membrane. If the intensity of the test band is weaker than the reference band (R), it indicates that the CRP level in the specimen is between 10-30 mg/L. If the intensity of the test band (T) is stronger than the reference band (R), it indicates that the CRP level is above 30 mg/L. The appearance of the control line serves as a procedural control, indicating that the proper volume of specimen has been added and membrane wicking has occurred.

Performance Characteristics

  • Relative sensitivity: >98.8%
  • Relative specificity: 98.7%
  • Accuracy: 98.7%

Storage Conditions

Store the kit between 2-30°C and ensure the kits are not frozen or stored in direct sunlight. The test is valid until the expiration date printed on the foil wrapping.

Quantitative CRP Rapid Test

Product Number: RAPG-CRP-101

Biopanda supplies a lateral flow chromatographic immunoassay for the quantitative detection of C-reactive Protein in whole blood, serum and plasma samples. The test is intended to be used with the BR-G8000 Handheld Immunoassay Analyzer.

Click here or on the image below to be taken the product page.




Please click on "button" below for pricing to be sent to you.

                      Pricing button

Biopanda Reagents is a test kit provider.
Customer satisfaction is our top priority.
  Biopanda Product Catalogue
Register for updates


 
Stay Connected
Facebook Linkedin

Manufacture
and market

quality reagents


Excellent Service

full technical
support